Skip to content

Inside the XGS 3300's switch chip: two ports bridged at 938 Mbit/s past the firewall, a VLAN in its table, an exact mirror, egress steps and one TCAM rule, 2026-11-11

On 2026-11-10 two front ports of the second XGS 3300 were switched to each other inside its 88E6193X switch chip, and one port was mirrored and its egress limited. These runs measured each with traffic. What does the chip carry when it switches two ports itself, and what does the firewall see of it? Does a VLAN loaded into the chip's own VLAN table work? How exact is the mirror, and what does it cost? Which egress limits does the chip offer? Does a rule of one's own fit in its TCAM, the table of rules the vendor's software fills?

The whole page, with how it was taken and what it does not show: Inside the XGS 3300's switch chip: two ports bridged at 938 Mbit/s past the firewall, a VLAN in its table, an exact mirror, egress steps and one TCAM rule, 2026-11-11.

Discussion

The discussion of this page is held in the project's GitHub Discussions. Showing it here loads giscus from giscus.app and GitHub, and writing in it needs a GitHub account - what that means.