How the measurements are taken

Every measurement page says how its numbers were taken and what they do not mean. This page gathers what all of them have in common: the bench, where a figure is read, the tools, the arithmetic behind each kind of figure, and the rules every page keeps - each with the reason it is done that way, because a figure without its method is not evidence of anything, and the ones that look best are usually the ones measuring something other than what they claim.

The bench

Two XGS 3300s and an XGS 136, routed to each other, and a PC on the middle one at 10 Gbit/s - as on the bench page, where each run's window is photographed:

link from to medium
the PC the PC's 10GBASE-T NIC the second XGS 3300's F1 copper, 10 Gbit/s
the fibre the second XGS 3300's module port A1 the first XGS 3300's F1 fibre, 10 Gbit/s
the gigabit link the second XGS 3300's Port8 the XGS 136's Port8 copper, 1 Gbit/s
what why
A hardware peer at both ends of every tunnel. Until 2026-10-17 the far end of a measured tunnel was a firewall doing ESP in software, so a figure could be that firewall's rather than the appliance's.
Each link a /30 of its own, out of the LAN bridge, with a pass rule and a static route. Traffic is routed through the appliance rather than switched past it, and nothing else on the network shares the path.
Never a public test server as the far end. Those are other people's servers and they refuse what looks like a flood; a refused line once left three "downloads" in a table that had never run. Anything parallel or repeated goes to a far end on the bench.

Where a figure is read

At the receiver, at the far end - never from the appliance's own counters. A connection in hardware goes from port to port inside the coprocessor and never reaches the host: pf's state, the interface counters and every graph built on them stop growing. A gauge that reads zero when things work is not a gauge - a run was once stopped by a rule that read such a zero as a collapse that never happened.

The receiver's figure, not the sender's. iperf3 prints both: the sender counts what it wrote into its socket, the receiver what arrived. Only the second is throughput.

A row is read only after it is known to have run - bytes received, not just counters moved.

The tools

tool what it measures here why this one
iperf3 - 3.20 under WSL on the PC to send, iperf3 for Windows to receive, 3.22 (OPNsense's package) as the server on an appliance's host throughput, one TCP stream or four, ten seconds a run the same tool at both ends of every run, its version named. Two clients on the PC because WSL's mirrored networking passes a frame above 1500 bytes out and not in: every run in which the PC received above 1500 measured 0.00 bits/s until it was measured again with the Windows build
curl over HTTPS, and SHA-256 the integrity soaks: a 1 GiB file of random bytes fetched in loops for hours TLS refuses any record that does not authenticate, and the file's hash against the server's catches anything that got through whole; throughput alone says nothing about whether the bytes were right
ping with the don't-fragment bit, at set sizes whether a frame of a given size crosses a path, and round trips the plainest test of a path's MTU and of a port that receives at all
sysctl the CPUs (kern.cp_time), the drivers' own counters (dev.octep.0.*, dev.npuep.0.*), and the TCP host cache emptied (net.inet.tcp.hostcache.purgenow) the kernel's own numbers, read the same way on every run
pfctl pf's states and their packet and byte counts what the host's firewall saw, to set beside what the hardware saw
the coprocessor's own statistics, read through the driver what the hardware forwarded: frames from the wire, frames it sent back to the wire itself, its count of each connection the only witness of the traffic the host no longer sees
mvsw the switch chip's registers: a port's frame limit, its error counters errors and limits that only the switch sees, read from its own registers
shot-run.ps1 runs each measuring command in a console window of its own and photographs that window when it finishes, with the window's own pixels the evidence is the screen as it was, not a rendering of the text retyped afterwards, and nothing else on the desktop gets into the picture
tools/mark-images.py puts the owner and the licence (CC BY 4.0) in a strip under every photograph; the unmarked original is kept apart a picture that leaves the page still says whose it is
tools/readme-art.py computes each appliance's completion from its family page's table see the arithmetic below; the checks fail if a page states anything else

The scripts that drive each run are named on the page of that run.

The arithmetic

figure how it is computed why
throughput, one run the receiver's bits per second over the run, as iperf3 prints it the receiver's count is what arrived
throughput, a soak bytes received in the passes that succeeded × 8, over the seconds from the first pass's start to the last one's end an average over hours, failures not counted as delivered
CPU busy kern.cp_time read before and after the run; busy = (total − idle) ÷ total, of the differences what the run cost over all of it, where a glance at top picks one moment
share of frames in hardware of the frames the coprocessor received from the wire over the run (RX_WIRE), the share it sent back to the wire itself (FROM_WIRE_TO_WIRE): 6,630,528 of 6,657,897 is 99.6 % counted by the hardware that forwarded them, not inferred from the host's silence
a counter, trusted set against an amount known beforehand: the PC sends exactly 4,000,000,000 bytes, and the coprocessor's count and pf's together must come to what crossed the wire - they came to it within 14 packets in 2.74 million a counter is trusted only after it has agreed with something counted independently; two were found wrong this way
an integrity soak's result passes that failed (curl's exit), passes whose file differed (the hash), and bytes a soak passes only if both are zero
an appliance's completion each row of its family page's table has a done percentage and a weight; completion = Σ(done × weight) ÷ N, where the weights add up to N and a struck value does not count a percentage that cannot drift from what it weighs: tools/readme-art.py computes it, and the checks fail if the page or the README says another

The rules every page keeps

rule why
How it was taken, and what it does not mean, on every page the limits of a figure are part of it: a stream that ends on an appliance's own host measures the smallest of the PC, the forwarding, the link and that host's receive path - not the forwarding ceiling, which needs a machine behind the far appliance
The build is named - the driver's commit or its checksum a number belongs to the code that produced it
Every window is photographed when its run finishes anyone can see the run, not a copy of its numbers; lab addresses are left in the pictures, serial numbers and hardware addresses are blurred
What a host has learned is forgotten before each run - its TCP host cache, and the PC's path-MTU cache a path MTU learned in one run was carried into the next: a whole pass ran with 500-byte segments and was thrown away
What went wrong in the measuring is written up the mistakes - a learned MTU, WSL's dropped frames - are why a page measured the way it did, and the next measurement avoids them
A withdrawn figure is struck, not deleted, the correction beside it a reader sees what changed, and why
The vendor's figures are labelled the vendor's, beside ours they come from Keysight-Ixia BreakingPoint under ideal conditions, with the MTU, the ports and whether both directions count not stated: not the same kind of number as one taken here

Where the numbers are

Every measurement, by appliance and by day: the measurements.