Re-read 2026-10-07. The headline did not survive either: the handle a flow names is the index plus one, so these trials each used the slot below the one they named. See the withdrawal under the table, and the handle is the index plus one.

Measured on an XGS 3300, 2026-10-06. FPCNTR_FROM_WIRE_TO_IPSEC_ENCR had been zero since this project began. It is not zero any more.

What changed

Nothing was built. The flow path finished in #256 and #257 made the experiment possible, and the experiment was four reads and one write per trial. A real transiting flow was accelerated, then its own entry was reprogrammed with MFLOW_PROGRAM to name a security association, and the far side's counters were read across two windows.

the association's lif_index what the far side did with the flow's frames
no association at all FROM_WIRE_TO_WIRE +17 - forwarded in hardware, in the clear
0 nothing. Not forwarded, not encrypted, every frame punted
10 - not interface 10; see below FROM_WIRE_TO_IPSEC_ENCR +7
0xa000 - oxp0's own LIF, (iface 10 << 12) \| vlan 0 FROM_WIRE_TO_IPSEC_ENCR +6

Withdrawn on 2026-10-07, in its turn: the microflow's handle is the association's index plus one, so each trial above used the slot below the one it named - the lif 0 association is the one that encrypted in the second row, and the first row measured an empty slot. A zero lif_index is not refused on an encrypt association. The measurement, with the SPI read off the wire at the peer, is the handle is the index plus one; the rest of this page stands as written, including its lesson, which it has now illustrated twice. The sentence that stood here before that - that the value must be the flow's ingress interface and that 10 and 0xa000 are two ways of writing it - was withdrawn first.

The vendor has one encoding, and the interface is the high bits: the shift is 12, so lif_index = (iface << 12) | vlan. Under it, 0xa000 is iface 10 with no VLAN - which is oxp0, and is the form the vendor's own host driver builds. But the bare 10 is iface 0 with VLAN 10, a different logical interface altogether, and not the flow's ingress port either. The two successful trials were not one interface written twice; they were two unrelated LIFs whose only shared property is being non-zero. No value naming a wrong non-zero interface has been tried.

And the reason cannot be anything this project can read, because for an encrypt association the far side's handler stores lif_index and never looks at it again. Its one interface-keyed structure, an SPI hash, is written only for a decrypt association - where a non-zero VLAN is refused outright, so the bare 10 would have failed on the inbound direction. Write the encoded form always: rc 0x0000 on an egress association says nothing about whether the LIF means what was intended.

Why this was not found before

Because of a refusal that reads like success. SA_ADD is not idempotent: it answers rc 0x0002 for an index that is already occupied, and installs nothing.

index 1, already in use rc 0x0002
index 5, free rc 0x0000
index 6, free, lif 10 rc 0x0000
index 7, free, lif 0xa000 rc 0x0000
index 5 again, now in use rc 0x0002

The LIF had been tried before, in both encodings, and recorded as ruled out. It was tried by re-installing the same index - which answered rc 0x0002 and left the first association exactly where it was. The negative was measuring the association it was trying to replace. Every trial here uses a fresh index for that reason, and the first thing to check about any SA_ADD is whether it said 0 or 2.

The flow entry was never the problem, and the entry itself says so

LO_MFLOW_READ - command 40 - answers cleanly when it is given a real mflow_id. It had been recorded as answering inconsistently; it was being asked for indices 0 to 7, which are not flows. Asked for the id a punted frame named, it returns 116 bytes: an 8-byte preamble, the 64-byte key, the 20-byte entry and the 24-byte operational block.

The operational block, read back after naming association 1:

opr_fl = 0x2e810001
         sa_index 1   action 1 FWD   dir 1   bridge_control 0xe   state 2 ACTIVE

The far side stored the association index and kept the flow ACTIVE. So when every frame was punted under FROM_WIRE_TO_KN_MFLOW_NOT_ACTIVE, the entry was not inactive - that counter is where a flow the fast path declines to use is charged, whatever the reason. Reading the entry back is what told the two apart, and no counter would have.

And the key confirms an encoding that had only been inferred. Addresses below are from the documentation ranges in place of the appliance's own:

key +0x00  lif_id      0x0000a000      (iface 10 << 12) | vlan 0  - oxp0
    +0x04  dst_mac     02:00:00:00:00:01    the bridge's address, the frame's gateway
    +0x0a  src_mac     02:00:00:00:00:42    the machine behind it
    +0x10  ethtype     0x0800
    +0x12  ip_family   2
    +0x13  ip_proto    6
    +0x14  dport 443   sport
    +0x18  sip4 198.51.100.120   dip4 192.0.2.10
    +0x20..0x3f        zero

What the counter means, corrected

FROM_WIRE_TO_IPSEC_ENCR means a frame was classified for encryption, not that it reached the engine. Its only increment site is in worker_ordered, which has zero references to the crypto globals page and runs long before anything is submitted - see both ends exist. The table above is unaffected: the association's lif_index is what decides whether a frame is classified at all, and that is what was measured. The phrase "reaches the engine" below was too strong when it was written and is kept so the correction has something to point at.

Where it stops now

The frames go into the crypto engine and nothing comes out of it. FPCNTR_RX_IPSEC - which is what a frame returning from the engine is charged to - did not move in either trial, and neither did any CRYPTO_DROP_* counter.

That is a different place from where this has been stuck. The earlier route - a host-injected frame marked for encryption in its metadata - reached crypto_pkt_submit and died at FPCNTR_CRYPTO_DROP_SADB_PRE_ERR, because the SA index the submit reads out of an mbuf dynamic field was never written. The flow route writes it from the entry, reaches the engine, and is not dropped by it: no drop counter moved at all. So the question is no longer why is the frame refused but where does an accepted frame go.

Worth noting what the counter list does and does not have: there is FROM_IPSEC_DECR_TO_WIRE for the inbound direction and no outbound completion counter at all. The outbound path's evidence is RX_IPSEC and then TX_WIRE, not a counter named for it - so an absence here has to be read carefully, and RX_IPSEC is the one to watch.

Lesson

A negative result is only as good as the write that produced it. SA_ADD answering rc 0x0002 looks like a completed command to anything that does not check, and it turned a parameter that was the answer into a parameter that had been ruled out - on this page's own evidence, for three days. Check the return of a write before believing anything measured after it, and prefer a fresh index to a re-used one, because a write that refuses to overwrite cannot be told from one that overwrote identically.